  (1/12) 003-01 / 20051205 / ea122_fmp.fm ? all specifications are subject to change without notice. ac input single output, general-purpose f series fmp/fmp-b(3 to 10w) the f series fmp/fmp-b has realized a thickness of 20mm max. by the tdk original technology such as increased switching fre- quencies and a thin-type transformer or filter. it has an equivalent level of the fcc class b in the noise terminal voltage in spite of the compact size. an onboard-type fmp-b is included in the lineup. features  ac.100v input thin-type single output power supply.  compact plastic package type.  low price.  low noise (fcc class b compliant).  it is a product conforming to rohs directive. ppart numbers and ratings fmp fmp-b  the above products are only produced upon receipt of order. please check a delivery date. conformity to rohs directive output voltage (v) 3w type 10w type current(a) part no. current(a) part no. 5 0.06 to 0.6 fmp05-r60 0.2 to 2 fmp05-2r0 12 0.02 to 0.25 fmp12-r25 0.08 to 0.85 fmp12-r85 24 0.01 to 0.13 fmp24-r13 0.04 to 0.45 FMP24-R45 output voltage (v) 3w type 10w type current(a) part no. current(a) part no. 5 0.06 to 0.6 fmp05-r60b 0.2 to 2 fmp05-2r0b 12 0.02 to 0.25 fmp12-r25b 0.08 to 0.85 fmp12-r85b 24 0.01 to 0.13 fmp24-r13b 0.04 to 0.45 FMP24-R45b  conformity to rohs directive: this means that, in conformity with eu directive 2002/95/ec, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, pbb and pbde, have not been used, except for exempted applications.
(2/12) 003-01 / 20051205 / ea122_fmp.fm  all specifications are subject to change without notice. fmp3w type specifications and standards ? 1 current rating(maximum output current) is determined for 0 to +50c. derating is required when used outside this temperature r ange. ? 2 the output load variation is determined within the range set by the minimum output current and the maximum output current. no minal values might possibly not be satisfied when output is below the minimum output current. ? 3 although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, the reby preventing overvoltage. ? 4 output may fail to come on when operated in series. part no. fmp05-r60 ? 4 fmp12-r25 fmp24-r13 rated output voltage and current ? 1 5v  0.6a 12v  0.25a 24v  0.13a maximum output power w 3 3 3.1 input conditions input voltage eac v 85 to 132[rating: 100 to 120] input frequency hz 47 to 440[rating: 50 to 60](single phase) input current a 0.1max./0.08typ.[ac.85v] surge current a 16max.[input and output ratings, 25c, cold start] leakage current ma 0.5max.[input and output ratings] efficiency % 68typ. 70typ. 74typ. output characteristics output voltage edc v 5 12 24 voltage variable range edc v 4.5 to 5.5 10.8 to 13.2 21.6 to 26.4 maximum output current a 0.6 0.25 0.13 minimum output current ? 2 a 0.06 0.02 0.01 overcurrent threshold a 0.7 to 1.2 0.3 to 0.5 0.15 to 0.3 voltage stability source effect % 0.1typ.[within the input voltage range] total effect 3max.(1typ.) load effect ? 2 % 0.8typ.[10 to 100% load] temperature effect % 1typ.[ambient temperature: 0 to +50c] drift(time effect) % 1max.[25c, input and output ratings, after input voltage on for 30min to 8h] recovery %/ms 4max./1max.[50 to 100% sudden load change] ripple ep-p mv 50max. 80max. 100max. ripple noise ep-p mv 100max. 150max. 150max. start up time ms 100max. hold up time ms 20min. auxiliary functions indicator display no overvoltage protection uses overvoltage prevention. ? 3 overcurrent protection rectangular type, automatic recovery. remote on-off no remote sensing no output voltage external variable function no standards safety standards ? noise terminal voltage fcc class b meet. constructions external dimensions mm 19 55 50[h w l](except input and output terminals) weight g 80max. mounting method can be attached to 1 side. case material nonflammable resin. input and output cables no
(3/12) 003-01 / 20051205 / ea122_fmp.fm  all specifications are subject to change without notice. fmp3w type shapes and dimensions  do not insert m3 installation screws more than 6mm into the power supply. (recommend torque 0.48n  m)  faston ? is registered trademark of tyco electronics amp corp. incorporated. terminal designations and functions terminal no. designations and functions 1 dc output terminals(+, ?) connect to load. 2 no connection (nc) connect none to this terminal. 3 frame ground terminal(g) connected to ground lead for input line. 4 ac input terminals(l, n, ac input) connect to ac.100 to 120v single phase input line. 10 (v. adj position) 4.75 6 ? 1.5 2-c1 3.2 (6.35) t=0.5 8.5 45?.4 (5) 5 (11.5) 6.5 6.5 6.5 8.5 8.5 7 50?.7 11max. 55?.7 40?.4 2-m3 tap (5) 5 13.5 (v. adj position) 19?.7 v.adj + nc l 0.1a 50-60h z 100-120v power supply fmp05-r60 n ? dc output ac input 5v 0.6a [detail drawing of terminal block(187 faston ? tab)] dimensions in mm 0.7mm: without specified dimensions v.adj + nc l 0.1a 50-60h z 100-120v power supply fmp05-r60 n ? dc output ac input 5v 0.6a 1 2 3 4
(4/12) 003-01 / 20051205 / ea122_fmp.fm  all specifications are subject to change without notice. fmp10w type specifications and standards ? 1 current rating(maximum output current) is determined for 0 to +50 c. derating is required when used outside this temperature range. ? 2 the output load variation is determined within the range set by the minimum output current and the maximum output current. no minal values might possibly not be satisfied when output is below the minimum output current. ? 3 although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, the reby preventing overvoltage. ? 4 output may fail to come on when operated in series. part no. fmp05-2r0 ? 4 fmp12-r85 FMP24-R45 rated output voltage and current ? 1 5v  2a 12v  0.85a 24v  0.45a maximum output power w 10 10.2 10.8 input conditions input voltage eac v 85 to 132[rating: 100 to 120] input frequency hz 47 to 440[rating: 50 to 60](single phase) input current a 0.35max./0.25typ.[ac.85v] surge current a 16max.[input and output ratings, 25 c, cold start] leakage current ma 0.5max.[input and output ratings] efficiency % 75typ. 78typ. 81typ. output characteristics output voltage edc v 5 12 24 voltage variable range edc v 4.5 to 5.5 10.8 to 13.2 21.6 to 26.4 maximum output current a 2 0.85 0.45 minimum output current ? 2 a 0.2 0.08 0.04 overcurrent threshold a 2.2 to 3.3 0.9 to 1.4 0.5 to 0.8 voltage stability source effect % 0.1typ.[within the input voltage range] total effect 3max.(1typ.) load effect ? 2 % 0.8typ.[10 to 100% load] temperature effect % 1typ.[ambient temperature: 0 to +50 c] drift(time effect) % 1max.[25 c, input and output ratings, after input voltage on for 30min to 8h] recovery %/ms ?max./1max.[50 to 100% sudden load change] ripple ep-p mv 50max. 80max. 100max. ripple noise ep-p mv 100max. 150max. 150max. start up time ms 100max. hold up time ms 20min. auxiliary functions indicator display no overvoltage protection uses overvoltage prevention. ? 3 overcurrent protection rectangular type, automatic recovery. remote on-off no remote sensing no output voltage external variable function no standards safety standards ? noise terminal voltage fcc class b meet. constructions external dimensions mm 19 55 80[h w l](except input and output terminals) weight g 100max. mounting method can be attached to 1 side. case material nonflammable resin. input and output cables no
(5/12) 003-01 / 20051205 / ea122_fmp.fm  all specifications are subject to change without notice. fmp10w type shapes and dimensions  do not insert m3 installation screws more than 6mm into the power supply. (recommend torque 0.48n  m)  faston ? is registered trademark of tyco electronics amp corp. incorporated. terminal designations and functions terminal no. designations and functions 1 dc output terminals(+, ? ) connect to load. 2 no connection (nc) connect none to this terminal. 3 frame ground terminal(g) connected to ground lead for input line. 4 ac input terminals(l, n, ac input) connect to ac.100 to 120v single phase input line. (11.5) 6.5 8.5 6.5 6.5 8.5 7 14.5 (v. adj position) v.adj + nc l 0.35a 50-60h z 100-120v power supply fmp05-2r0 n ? dc output ac input 5v 2a 8.5 80?.7 v. adj trimmer on opposite. 11max. 19?.7 55?.7 45?.4 (5) 5 70?.4 2-m3 tap (5) 5 10 (v. adj position) 4.75 6 ? 1.5 2-c1 3.2 (6.35) t=0.5 [detail drawing of terminal block(187 faston ? tab)] dimensions in mm 0.7mm : without specified dimensions v.adj nc l 0.35a 50-60h z 100-120v power supply fmp05-2r0 n dc output ac input 5v 2a 1 2 3 4 + ?
(6/12) 003-01 / 20051205 / ea122_fmp.fm  all specifications are subject to change without notice. fmp-b3w type specifications and standards ? 1 current rating(maximum output current) is determined for 0 to +50 c. derating is required when used outside this temperature range. ? 2 the output load variation is determined within the range set by the minimum output current and the maximum output current. no minal values might possibly not be satisfied when output is below the minimum output current. ? 3 although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, the reby preventing overvoltage. ? 4 output may fail to come on when operated in series. part no. fmp05-r60b ? 4 fmp12-r25b fmp24-r13b rated output voltage and current ? 1 5v  0.6a 12v  0.25a 24v  0.13a maximum output power w 3 3 3.1 input conditions input voltage eac v 85 to 132[rating: 100 to 120] input frequency hz 47 to 440[rating: 50 to 60](single phase) input current a 0.1max./0.08typ.[ac.85v] surge current a 16max.[input and output ratings, 25 c, cold start] leakage current ma 0.5max.[input and output ratings] efficiency % 68typ. 70typ. 74typ. output characteristics output voltage edc v 5 12 24 voltage variable range edc v 4.5 to 5.5 10.8 to 13.2 21.6 to 26.4 maximum output current a 0.6 0.25 0.13 minimum output current ? 2 a 0.06 0.02 0.01 overcurrent threshold a 0.7 to 1.2 0.3 to 0.5 0.15 to 0.3 voltage stability source effect % 0.1typ.[within the input voltage range] total effect 3max.(1typ.) load effect ? 2 % 0.8typ.[10 to 100% load] temperature effect % 1typ.[ambient temperature: 0 to +50 c] drift(time effect) % 1max.[25 c, input and output ratings, after input voltage on for 30min to 8h] recovery %/ms ?max./1max.[50 to 100% sudden load change] ripple ep-p mv 50max. 80max. 100max. ripple noise ep-p mv 100max. 150max. 150max. start up time ms 100max. hold up time ms 20min. auxiliary functions indicator display no overvoltage protection uses overvoltage prevention. ? 3 overcurrent protection rectangular type, automatic recovery. remote on-off no remote sensing no output voltage external variable function no standards safety standards ? noise terminal voltage fcc class b meet. constructions external dimensions mm 19 55 50[h w l](except input and output terminals) weight g 80max. mounting method can be attached to 1 side. case material nonflammable resin. input and output cables no
(7/12) 003-01 / 20051205 / ea122_fmp.fm  all specifications are subject to change without notice. fmp-b3w type shapes and dimensions  do not insert m3 installation screws more than 6mm into the power supply. (recommend torque 0.48n  m)  when mounted on pcb, must solder after insert m3. terminal designations and functions terminal no. designations and functions 1 dc output terminals(+, ? ) connect to load. 2 no connection (nc) connect none to this terminal. 3 frame ground terminal(g) connected to ground lead for input line. 4 ac input terminals(l, n, ac input) connect to ac.100 to 120v single phase input line. 55 10 (v. adj position) 13.5 (v. adj position) v.adj + nc l 0.1a 50-60h z 100-120v power supply fmp05-r60b n ? dc output ac input 5v 0.6a t=0.5 50 up 4 19 1.2?.2 r 7 8.5?.3 6.5?.3 6.5?.3 8.5?.3 41?.5 4?.5 m3 tap 5?.3 (5) 6.5?.3 (11.5) dimensions in mm ?.7mm : without specified dimensions v.adj nc l 0.1a 50-60h z 100-120v power supply fmp05-r60b n dc output ac input 5v 0.6a 1 3 2 4 + ?
(8/12) 003-01 / 20051205 / ea122_fmp.fm  all specifications are subject to change without notice. fmp-b10w type specifications and standards ? 1 current rating(maximum output current) is determined for 0 to +50 c. derating is required when used outside this temperature range. ? 2 the output load variation is determined within the range set by the minimum output current and the maximum output current. no minal values might possibly not be satisfied when output is below the minimum output current. ? 3 although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, the reby preventing overvoltage. ? 4 output may fail to come on when operated in series. part no. fmp05-2r0b ? 4 fmp12-r85b FMP24-R45b rated output voltage and current ? 1 5v  2a 12v  0.85a 24v  0.45a maximum output power w 10 10.2 10.8 input conditions input voltage eac v 85 to 132[rating: 100 to 120] input frequency hz 47 to 440[rating: 50 to 60](single phase) input current a 0.35max./0.25typ.[ac.85v] surge current a 16max.[input and output ratings, 25 c, cold start] leakage current ma 0.5max.[input and output ratings] efficiency % 75typ. 78typ. 81typ. output characteristics output voltage edc v 5 12 24 voltage variable range edc v 4.5 to 5.5 10.8 to 13.2 21.6 to 26.4 maximum output current a 2 0.85 0.45 minimum output current ? 2 a 0.2 0.08 0.04 overcurrent threshold a 2.2 to 3.3 0.9 to 1.4 0.5 to 0.8 voltage stability source effect % 0.1typ.[within the input voltage range] total effect 3max.(1typ.) load effect ? 2 % 0.8typ.[10 to 100% load] temperature effect % 1typ.[ambient temperature: 0 to +50 c] drift(time effect) % 1max.[25 c, input and output ratings, after input voltage on for 30min to 8h] recovery %/ms ?max./1max.[50 to 100% sudden load change] ripple ep-p mv 50max. 80max. 100max. ripple noise ep-p mv 100max. 150max. 150max. start up time ms 100max. hold up time ms 20min. auxiliary functions indicator display no overvoltage protection uses overvoltage prevention. ? 3 overcurrent protection rectangular type, automatic recovery. remote on-off no remote sensing no output voltage external variable function no standards safety standards ? noise terminal voltage fcc class b meet. constructions external dimensions mm 19 55 80[h w l](except input and output terminals) weight g 100max. mounting method can be attached to 1 side. case material nonflammable resin. input and output cables no
(9/12) 003-01 / 20051205 / ea122_fmp.fm  all specifications are subject to change without notice. fmp-b10w type shapes and dimensions  do not insert m3 installation screws more than 6mm into the power supply. (recommend torque 0.48n  m)  when mounted on pcb, must solder after insert m3. terminal designations and functions terminal no. designations and functions 1 dc output terminals(+, ? ) connect to load. 2 no connection (nc) connect none to this terminal. 3 frame ground terminal(g) connected to ground lead for input line. 4 ac input terminals(l, n, ac input) connect to ac.100 to 120v single phase input line. 7 8.5?.3 6.5?.3 6.5?.3 8.5?.3 71?.5 4?.5 m3 tap 5?.3 (5) 6.5?.3 (11.5) 55 10 (v. adj position) t=0.5 80 up 4 1.2?.2 r 19 14.5 (v. adj position) v.adj + nc l 0.35a 50-60h z 100-120v power fmp05-2r0b n ? dc output ac input 5v 2a dimensions in mm 0.7mm: without specified dimensions v.adj nc l 0.35a 50-60h z 100-120v power fmp05-2r0b n dc output ac input 5v 2a 1 3 2 4 + ?
(10/12) 003-01 / 20051205 / ea122_fmp.fm  all specifications are subject to change without notice. characteristics, functions, and applications common specifications block diagram output power-ambient temperature(deratings) temperature and humidity temperature range operating( c) 0 to +60[derating is necessary when operating environment temperature exceed 50 c.] storage( c) ? 25 to +75 humidity range operating(%)rh 20 to 95[maximum wet-bulb temperature: 35 c, without dewing] storage(%)rh vibration and shock vibration 5 to 10hz all amplitude 10mm[3 directions, each 1h] 10 to 55hz acceleration 19.6m/s 2 (2g)[3 directions, each 1h] shock acceleration 196m/s 2 (20g)[3 directions, each 3 times] pulse duration 115ms withstand voltage and insulation resistance withstand voltage input terminal to ground terminal(g) eac: 2kv, 1min[normal temperature, normal humidity, cutout current 10ma] input terminal to output terminal insulation resistance input terminal to ground terminal(g) edc: 500v, 100m ? min. [normal temperature, normal humidity] input terminal to output terminal output terminal to ground terminal(g) l n ac input + ? dc output input fitter circuit input current circuit input smoothing circuit surge current limiting circuit over- current detection circuit power switching circuit drive circuit control circuit control circuit output rectifying and smoothing circuit 100 80 60 40 20 ? 10 0 10 20 30 40 50 60 ambient temperature(?c) output power(%) available operating range (outside of warranty)
(11/12) 003-01 / 20051205 / ea122_fmp.fm all specifications are subject to change without notice. characteristics, functions, and applications start up time(25c, rated input and output) 3w type 10w type hold up time(25c, rated input and output) 3w type 10w type three numeric values in the above data indicate output voltages which may reach 90% or higher of the rated output voltage at the input voltage ac.85/100/132v. output voltage characteristics 3w type 10w type fmp05-r60 h:10ms/div (4/4/4)ms output voltage ac input fmp05-2r0 h:10ms/div (6.5/6/5)ms output voltage ac input fmp05-r60 h:10ms/div output voltage(20/42/54)ms ac input fmp05-2r0 h:10ms/div output voltage(14/24/30)ms ac input 6 5 4 3 2 1 output voltage ( v ) fmp05-r60 132v 100v 80v 100 load(%) 6 5 4 3 2 1 output voltage ( v ) fmp05-2r0 85v 132v 100v 100(2a) 200 load(%)
(12/12) 003-01 / 20051205 / ea122_fmp.fm all specifications are subject to change without notice. characteristics, functions, and applications input/output terminal for input/output terminals, 187-type faston tabs are used. these terminals are commercially available from various terminal manu- facturers. two manufacturing companies among them will be intro- duced below. these terminals can be soldered, though it is undesirable to heat them for a long time. 187 tab product introduction a 4.8 mm series tab connection terminal (187 tab-on connector) unit: mm ? 1 jis standard product (jis c2809). the number in parentheses ( ) indicates a conventional part number. ? 2 ul registered product. this data is cited from the catalog no. ter-017a-14p (p. 8) of japan pressure terminal sales co., ltd., titled "continuous pres sure terminal and connector." 187 tab product introduction b 187 series receptacle unit: mm ? no preform of a wire barrel. this data is cited from the catalog no. f.ff-21 (p. 20) of tyco electronics amp corp. titled "faston connector and fastine faston connector." input fuse these products have no embedded f series, fmp, and input fuse. to further improve safety of an fmp-embedded device, it is rec- ommended to mount a fuse on an ac input terminal (l side). ratings of recommended external fuse fmp3w: 0.63a fmp10w: 1a other conditions unless conditions are otherwise specified in the specifications or standards, 25 c and rated input-output should be applied. ripple and noise (50mhz max.) were determined for 0 to +50 c temperature range and 10 to 100% load. w t e l chamfered applicable tab thickness 6.35 3.2 4.75 (see the description marked ? in the table below.) part no. applicable wires material surface treatment wl e t (approx.) plate thickness thickness of applicable tab ? quantity/ reel continuous terminal range of applicable wires(mm 2 ) external diameter of insulated coating(mm) sto-01-187n 0.2 to 0.5 1.5 to 2.6 brass 5.6 15 6.3 1.5 0.32 0.5 10,000 fs4.8b-0.5-5(sto-01t-187n) ? 1 ? 2 tinning sto-41-187n ? 2 0.5 to 1.25 2.6 to 3.5 brass 5.6 15 6.3 1.5 0.32 0.5 10,000 fs4.8b-1.25-5(sto-41-187n) ? 1 ? 2 tinning range of applicable wires thickness of tab in the other side plate thickness size material and finishing part no. of receptacle quantity per reel unit: thousand awg (mm 2 ) external diameter of coating l t in chain in loose 24-20 0.2 to 0.56 1.02 to 1.78 0.51 0.3 15 1.5 brass 60573-2 60711-2 ? 20 brass and tin 60573-1 60711-1 ? 1.5 to 2.5 0.5 0.32 170214-2 170203-2 9 20-16 0.5 to 1.42 2.29 to 3.3 0.51 0.3 14.9 1.5 copper and nickel 60621-1 61020-1 ? 20 0.32 15.2 brass 170037-1 170038-1 9 brass and tin 170037-2 170038-2 phosphor bronze and tin170037-4 170038-4 18-16 or 18 2 0.75 to 1.42 or (0.75 to 0.89) 2 2.67 2 max. 0.51 0.3 15 1 brass and tin 60487-2 20 18-14 0.75 to 2.27 2.2 to 3.4 0.51 0.3 15.2 1.5 phosphor bronze and tin170466-1 170467-1 9 faston and fastine faston is registered trademark of tyco electronics amp corp. incorporated.


▲Up To Search▲   

 
Price & Availability of FMP24-R45

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X